VOLTAMMETRIC ON LINE ANALYZER FOR TPb/TCd MONITORING IN WATER

MICROMAC TOTAL LEAD AND TOTAL CADMIUM VOLTAMMETRIC ON LINE ANALYZER

MICROMAC Total Lead/Total Cadmium is a microprocessor controlled online analyzer specifically designed for automatic and multiparametric TPb/TCd monitoring on several types of waters matrices.

ROBUST AND RELIABLE

Designed for industrial and environmental online control applications it ensures the highest level of robustness in the electronics, mechanics and hydraulics components. Complete separation between electronics and hydraulics, plus a simple and robust hydraulics, allows easy maintenance and long terms reliable operations.

 

KNOWN ADDITION

After the sample pretreatment and as part of the measurement process the sample is spiked with two solutions at known concentration. The sample concentration of Lead and Cadmium in the sample are calculated using the known standard additions measurements.

 

EASY TO INSTALL

The online analyzer is delivered after a long and successful series of factory tests ready for installation and setup; it is provided with complete set of spares for start up. To start monitoring is enough to connect reagents, sample line, nitrogen line, waste line and power supply.

 

MEASURING INTERVAL

User selectable; between two measurements the analyzer remains in stand by mode, without reagents consumption.

 

FEATURES AND BENEFITS

  • Fully automatic operation
  • Long autonomy; low maintenance, low operating cost
  • Low reagents consumption; short preparation time; low disposable costs
  • Easy operation; plug in analyzer, no special training is required
  • Electronics and hydraulics completely separated
  • Serial interface for local to remote connection.

 

TPb/TCd measuring principle and hydraulic diagram

This method uses the Anodic Stripping Voltammetry. In this automated method the sample is acidified and heated to degrade all the organic substance, which would interfere with the measurement. During digestion, in the measuring cell mercury deposition is performed on the glassy graphite electrode. After digestion, the sample is transferred to the measuring cell where it is degassed with nitrogen for the removal of dissolved oxygen. The measurement of the concentration is performed in three steps.

Initially, cathodic deposition of the sample at -950 mV and anodic stripping of the sample from -950 mV to -50 mV are performed. Subsequently, the same operations are performed with the sample and the two known calibrant additions, through which the concentration of Lead and Cadmium in the sample are calculated.

 

Technical Specifications

MEASURING PRINCIPLE Anodic Stripping Voltammetry
MEASUREMENT TYPE cyclic
MEASURING INTERVAL programmable
MEASURING TIME about 50 minutes depending on sample type/the range
WORKING RANGE up to 100 ppb either Total Pb or Total Cd
ACCURACY at 5 ppb average of 7 replicates ≤10% both TPb/TCd
REPEATABILITY at 5 ppb, SD% of 7 replicates ≤10% both TPb/TCd
DETECTION LIMIT SD of 7 replicates at 5 ppb x 3,14, – ≤ 1,0 ppb both TPb/TCd
OUTPUT SIGNAL 4-20 mA
INPUT SIGNALS n. 1 Analysis, n. 1 calibration; digital contacts
ALARMS n. 1 High Limit, n. 1 General, n. 1 Calibration; potential free contacts
NITROGEN LINE Nitrogen type C, Pressure: 0,5 bar, Flow rate 200-300mL/min
SAMPLE AND WASTE DELIVERY pressure free
SAMPLE TEMPERATURE 10 °C – 30 °C
REAGENTS REPLACEMENT 3/4 weeks depending on the operating temperature
PROTECTION IP55
HARDWARE PC104 industrial standard, Integrated keyboard and graphics display, RS232 serial port
POWER SUPPLY 12 VDC external power supply from local power included
WEIGHT / DIMENSIONS 33 Kg without reagents / 800x420x280 mm (hxwxd)